Features & Benefits

  • COP: up to 4.3 (+7°C/+35°C)
  • Compatible with all kinds of low temperature transmitters
  • Intuitive control and simplified use
  • Navistem 400S regulator
  • 3kW Electrical back-up integrated (9kW three phase models)
  • Perfect solution for high heating demand
  • 16L buffer tank integrated
  • Patented coaxial heat exchanger
  • Inverter regulation
  • Possibility to manage electric radiator heating zone from heat pump control panel

Warranty

8 year warranty when commissioned by a GA approved engineer. Subject to terms & conditions.

Technical Specification

Designation Unit Alfea Excellia A.I 11 Alfea Excellia A.I 14 Alfea Axcellia A.I TRI 11 Alfea Excellia A.I TRI 14 Alfea Excellia A.I TRI 16
PRODUCT CODE AH526350 AH526351 AH526352 AH526353 AH526354
Refrigerant R410A R410A R410A R410A R410A
Heating capacity +7°C/+35°C - floor heating kW 10.80 13.50 10.80 13.00 15.17
COP +7°C/+35°C - floor heating 4.25 4.18 4.30 4.18 4.10
Heating capacity -7°C/+35°C - floor heating kW 10.38 11.54 10.38 12.20 12.98
COP -7°C/+35°C - floor heating 2.40 2.27 2.43 2.38 2.40
Heating capacity +7°C/+45°C - Low T° radiators kW 9.05 11.32 9.90 12.10 12.75
COP +7°C/+45°C - Low T° radiators 3.21 3.07 3.32 3.20 3.21
Heating capacity -7°C/+45°C - Low T° radiators kW 9.16 11.41 9.98 10.70 12.95
COP -7°C/+45°C - Low T° radiators 2.00 1.93 2.16 2.08 2.03
Heating capacity +7°C/+55°C - radiators kW 7.59 9.48 9.29 10.60 12.71
COP +7°C/+55°C - radiators 2.47 2.40 2.64 2.41 2.52
Heating capacity -7°C/+55°C - radiators kW 7.57 9.20 9.27 10.10 12.00
COP -7°C/+55°C - radiators 1.66 1.81 1.82 1.79 1.74
Heating capacity +7°C/+60°C - radiators kW 7.05 8.81 9.25 11.50 12.49
Heating capacity -7°C/+60°C - radiators kW 6.71 8.42 8.48 10.10 10.90
Electric back-up heater (standard) kW 3 3 9 9 9
Energy Efficiency & Acoustic Characteristics with Outdoor Sensor
Energy class - heating (35°C/55°C) - A++/A+ A++/A+ A++/A+ A++/A+ A++/A+
Thermal power (35°C/55°C) kW 11/9 13/11 11/9 13/11 14/13
Seasonal energy efficiency - heating (35°C/55°C) % 153/111 150/115 156/114 152/119 151/119
Annual energy consumption - heating (35°C/55°C) kWh 6062/6842 6824/8041 5930/6669 6738/7803 7408/9062
Sound power level (indoor/outdoor) dB(A) 46/69 46/70 46/68 46/69 46/70
Indoor Hydraulic Module
Noise level* dB(A) 39 39 39 39 39
Dimensions h x w x d mm 800x450x480 800x450x480 800x450x480 800x450x480 800x450x480
Net weight/filled weight kg 42/58 42/58 42/58 42/58 42/58
Outdoor unit
Power supply 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz
Noise level* * dB(A) 47 48 46 47 48
Dimensions h x w x d mm 1290x900x400 1290x900x400 1290x900x400 1290x900x400 1290x900x400
Operating weight kg 92 92 99 99 99
Refrigerant Charateristics
Min./max. length m 5/20 5/20 5/20 5/20 5/20
Max. diff. in height m 15 15 15 15 15