Features & Benefits

  • COP: up to 5.07 (+7°C / +35°C)
  • Intuitive and simple to use controls
  • 3kW Electrical back-up integrated (9kW three phase models)
  • Integrated magnetic filter
  • Inverter modulation
  • Compatible with all low temperature heating emitters
  • Up to A+++ ErP energy class
  • Low energy consumption circulating pump
  • Plate heat exchanger
  • Space Saving indoor Hydraulic module
  • R32 Refrigerant
  • Easy installation & maintenance
  • Domestic Hot Water (DHW) storage tank integrated (190L)

Warranty

5 year warranty when commissioned by a GA approved engineer. Subject to terms & conditions.

Designation Unit Atlantic Loria Duo 6003 R32 Atlantic Loria Duo 6004 R32 Atlantic Loria Duo 6006 R32 Atlantic Loria Duo 6008 R32 Atlantic Loria Duo 6010 R32
PRODUCT CODE AH526121 AH526122 AH526123 AH526124 AH526125
Heat Pump Space Heating [35°C]
ErP Rating A+++ A+++ A+++ A+++ A+++
𝜂𝑠 181% 182% 190% 185% 186%
SCOP 4.60 4.61 4.82 4.70 4.73
Heat Pump Space Heating [55°C]
ErP Rating A++ A++ A++ A++ A++
𝜂𝑠 126% 128% 132% 134% 139%
SCOP 3.22 3.29 3.36 3.41 3.54
Heating (A7/W35)
Capacity (kW) 3.3 4.6 5.6 7.5 9.8
Power Input (kW) 0.67 0.95 1.16 1.66 2.16
COP 5.07 4.83 4.81 4.52 4.53
Air Temperature Range (°C)
[Min/Max] -20/+35 -20/+35 -20/+35 -20/+35 -20/+35
Sound Data[Outdoor Unit / Indoor Unit]
Pressure Level [5m Outdoor /1m Indoor] (dBA) 35/36 35/36 35/36 38/36 40/36
Power Level (dBA) 57/44 57/44 57/44 60/44 62/44
Primary Flow Rate
Minimum (l/min) 7 7 10 10 10
Pipework Connection Sizes
Heating F/R (in) 1 1 1 1 1
Gas Pipe - refrigeration (in) 1/2 1/2 1/2 1/2 5/8
Liquid Pipe - refrigeration (in) 1/4 1/4 1/4 1/4 3/8
Dimensions (mm) Outdoor Unit
Width 886 886 886 907 977
Depth 325 325 325 349 372
Height 632 632 632 716 830
Dimensions (mm) Indoor Unit
Width 600 600 600 600 600
Depth 650 650 650 650 650
Height 1750 1750 1750 1750 1750
Weight (kg)
[Outdoor Unit / Indoor Unit] 39/135 39/135 39/135 42/135 62/135
Electrical Data
Electrical Supply (50 Hz) 230 V 230 V 230 V 230 V 230 V
Phase Single Single Single Single Single
Back-up Heater (kW) 3 3 3 3 3
Fuse Rating - MCB Sizes Type C (A) 16 16 16 20 32
Refrigerant Charge (kg)
R32 0.97 0.97 0.97 1.02 1.63

Find An Ideal Supplier In Your Area

For your local merchant please contact Ideal Energy Distribution Ltd on +35319617700 or email [email protected]

Our awards