| Designation | Unit | Atlantic Loria 6004 R32 | Atlantic Loria 6006 R32 | Atlantic Loria 6008 R32 | Atlantic Loria 6010 R32 | 
|---|---|---|---|---|---|
| PRODUCT CODE | AH526117 | AH526118 | AH526119 | AH526120 | |
| Heat Pump Space Heating [35°C] | |||||
| ErP Rating | A+++ | A+++ | A+++ | A+++ | |
| 𝜂𝑠 | 182% | 190% | 185% | 186% | |
| SCOP | 4.61 | 4.82 | 4.70 | 4.73 | |
| Heat Pump Space Heating [55°C] | |||||
| ErP Rating | A++ | A++ | A++ | A++ | |
| 𝜂𝑠 | 128% | 132% | 134% | 139% | |
| SCOP | 3.29 | 3.36 | 3.41 | 3.54 | |
| Heating (A7/W35) | |||||
| Capacity (kW) | 4.6 | 5.6 | 7.5 | 9.8 | |
| Power Input (kW) | 0.95 | 1.16 | 1.66 | 2.16 | |
| COP | 4.83 | 4.81 | 4.52 | 4.53 | |
| Air Temperature Range (°C) | |||||
| [Min/Max] | -20/+35 | -20/+35 | -20/+35 | -20/+35 | |
| Sound Data[Outdoor Unit / Indoor Unit] | |||||
| Pressure Level [5m Outdoor /1m Indoor] (dBA) | 35/36 | 35/36 | 38/36 | 40/36 | |
| Power Level (dBA) | 57/40 | 57/40 | 60/40 | 62/40 | |
| Primary Flow Rate | |||||
| Minimum (l/min) | 7 | 10 | 10 | 10 | |
| Pipework Connection Sizes | |||||
| Heating F/R (in) | 1 | 1 | 1 | 1 | |
| Gas Pipe - refrigeration (in) | 1/2 | 1/2 | 1/2 | 5/8 | |
| Liquid Pipe - refrigeration (in) | 1/4 | 1/4 | 1/4 | 3/8 | |
| Dimensions (mm)Outdoor Unit | |||||
| Width | 886 | 886 | 907 | 977 | |
| Depth | 325 | 325 | 349 | 372 | |
| Height | 632 | 632 | 716 | 830 | |
| Dimensions (mm) Indoor Unit | |||||
| Width | 550 | 550 | 550 | 550 | |
| Depth | 320 | 320 | 320 | 320 | |
| Height | 950 | 950 | 950 | 950 | |
| Weight (kg) | |||||
| [Outdoor Unit / Indoor Unit] | 39/42 | 39/42 | 42/42 | 62/42 | |
| Electrical Data | |||||
| Electrical Supply (50 Hz) | 230 V | 230 V | 230 V | 230 V | |
| Phase | Single | Single | Single | Single | |
| Maximum Running Current [Nominal] (A) | 24.05 [11] | 25.55 [12.5] | 30.55 [17.5] | 31.55 [18.5] | |
| Back-up Heater (kW) | 3 | 3 | 3 | 3 | |
| Fuse Rating - MCB Sizes Type C (A) | 16 | 16 | 20 | 32 | |
| Refrigerant Charge (kg) | |||||
| R32 | 0.97 | 0.97 | 1.02 | 1.63 | |
Only fully trained and approved professional installers can fit Ideal boilers, so step 1 in your purchase is to choose your local Ideal installer.